Step | Action | Value | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Were you sent here from the A/C System Performance Test? | -- | Go to Step 2 | |||||||||||||
2 |
Caution: Refer to Moving Parts and Hot Surfaces Caution in the Preface section. Feel the liquid line before the expansion device. Is the liquid line cold before the expansion device? | -- | Go to Step 3 | Go to Step 8 | ||||||||||||
3 | Feel along the surfaces of the following high side components for a sudden drop in temperature (the high side components should feel warm/hot from the compressor all the way to the expansion device).
Is there an abrupt drop in temperature noted along the surfaces of any of the listed components? | -- | Go to Step 7 | Go to Step 4 | ||||||||||||
4 |
Is the liquid line extremely cold at the expansion device location and warm after the expansion device location? | -- | Go to Step 11 | Go to Step 5 | ||||||||||||
5 | Feel along the surfaces of the following low side components for a sudden change in temperature.
Is there an abrupt temperature change felt along the surfaces of any of the listed components? | -- | Go to Step 7 | Go to Step 6 | ||||||||||||
6 | Feel along the surfaces of low and high side components to compare the overall temperatures.
Are the overall temperatures of the low and high side components close to the same: both only mildly warm? | -- | Go to Step 14 | Go to Step 8 | ||||||||||||
7 |
Is the repair complete? | -- | Go to Step 9 | -- | ||||||||||||
8 |
Is the weight of the recovered refrigerant charge equal to or above the specified value? | 0.71 kg (1.57 lb) | Go to Step 9 | Go to Step 10 | ||||||||||||
9 | Recharge the A/C system. Refer to Refrigerant Recovery and Recharging . Is the cooling performance improved? | -- | Go to Step 21 | Go to Step 10 | ||||||||||||
10 |
Is the repair complete? | -- | Go to Step 21 | -- | ||||||||||||
11 |
Are there metal flakes present? | -- | Go to Step 12 | Go to Step 13 | ||||||||||||
12 |
Is there a large amount of debris collected in the shop towel? | -- | Go to Step 18 | Go to Step 20 | ||||||||||||
13 | If the expansion device was restricted with a brown/black residue, perform the following:
Are the repairs complete? | -- | Go to Step 21 | -- | ||||||||||||
14 |
Is there debris present in the compressor suction port? | -- | Go to Step 15 | Go to Step 19 | ||||||||||||
15 |
Is there evidence of damage or debris? | -- | Go to Step 17 | Go to Step 16 | ||||||||||||
16 | If the expansion device does not show any signs of damage or debris:
Is there a large amount of debris collected in the shop towel? | -- | Go to Step 18 | Go to Step 19 | ||||||||||||
17 |
Are there metal flakes present? | -- | Go to Step 12 | Go to Step 13 | ||||||||||||
18 | If there was a large amount of debris collected in the shop towel from the compressor hose assembly, replace the receiver dehydrator. Refer to Receiver Dehydrator Replacement . Is the repair complete? | -- | Go to Step 19 | -- | ||||||||||||
19 | Install the compressor hose assembly. Refer to Compressor Hose Assembly Replacement . Are the repairs complete? | -- | Go to Step 21 | -- | ||||||||||||
20 |
Are the repairs complete? | -- | Go to Step 21 | -- | ||||||||||||
21 | Record the low and high side pressures and the IP outlet air temperature after repairs are performed. Compare the pressures and outlet temperature to those listed in the A/C Performance Chart. Refer to Air Conditioning (A/C) System Performance Test . Are the readings within the specified ranges? | -- | Go to Step 22 | |||||||||||||
22 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK |