Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 4 | Go to Step 3 | |||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 175-216 kPa (25-31 psi) | 680-840 kPa (99-122 psi) | 10°C (50°F) |
19-23°C (66-75°F) | Less than 40% | 175-245 kPa (25-36 psi) | 920-1140 kPa (134-166 psi) | 12°C (54°F) |
Greater than 40% | 176-256 kPa (26-37 psi) | 850-1100 kPa (123-160 psi) | 13°C (55°F) | |
24-29°C (76-85°F) | Less than 35% | 198-267 kPa (29-39 psi) | 1080-1310 kPa (157-190 psi) | 14°C (57°F) |
35-60% | 203-272 kPa (30-40 psi) | 1060-1310 kPa (154-190 psi) | 14°C (57°F) | |
Greater than 60% | 207-281 kPa (30-41 psi) | 1050-1310 kPa (152-190 psi) | 15°C (59°F) | |
30-35°C (86-95°F) | Less than 30% | 221-294 kPa (32-43 psi) | 1230-1510 kPa (179-219 psi) | 16°C (61°F) |
30-50% | 226-301 kPa (33-44 psi) | 1230-1530 kPa (179-222 psi) | 17°C (63°F) | |
Greater than 50% | 232-311 kPa (34-45 psi) | 1230-1570 kPa (179-228 psi) | 18°C (64°F) | |
36-40°C (96-105°F) | Less than 20% | 248-319 kPa (36-46 psi) | 1400-1680 kPa (203-244 psi) | 18°C (64°F) |
20-40% | 251-327 kPa (36-48 psi) | 1410-1730 kPa (205-251 psi) | 19°C (66°F) | |
Greater than 40% | 258-334 kPa (37-49 psi) | 1440-1780 kPa (209-258 psi) | 20°C (68°F) | |
41-46°C (106-115°F) | Less than 20% | 276-343 kPa (40-50 psi) | 1570-1830 kPa (228-266 psi) | 20°C (68°F) |
Greater than 20% | 279-351 kPa (41-51 psi) | 1600-1900 kPa (232-276 psi) | 21°C (70°F) | |
47-49°C (116-120°F) | Less than 30% | 303-361 kPa (44-52 psi) | 1750-1960 kPa (254-285 psi) | 21°C (70°F) |