Step | Action | Value | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: The high and low side pressures may be normal or slightly less than normal.
| ||||||||||
1 | Were you sent here from the air conditioning (A/C) System Performance Test? | -- | Go to Step 2 | |||||||
2 | Refer to the instrument panel outlet air temperatures recorded during the A/C system performance test. Does the discharge air temperature between the right and left center instrument panel outlets vary by more than 1-2°C (2-3°F)? | -- | Go to Step 7 | Go to Step 3 | ||||||
3 | Did the customer mention that the A/C system output temperatures are good at first, but then turn warm during extended drives? | -- | Go to Step 4 | Go to Step 5 | ||||||
4 | Increase engine speed to 2,000 RPM. During extended operation of the A/C system, does the low side pressure decrease, possibly accompanied by heavy frost on the liquid line between the expansion device and the evaporator? | -- | Go to Step 5 | |||||||
5 |
Warning: Refer to Moving Parts and Hot Surfaces Warning in the Preface section.
Do the listed conditions exist? | -- | Go to Step 7 | Go to Step 6 | ||||||
6 |
Do the listed conditions exist? | -- | Go to Step 8 | |||||||
7 | The A/C system may be undercharged.
Is the action complete? | -- | Go to Step 14 | -- | ||||||
8 | The A/C system may be contaminated. View the information screen on J 43600 for detection of foreign gases in the A/C system. Do foreign gases exist? | -- | Go to Step 9 | Go to Step 10 | ||||||
9 |
Is the action complete? | -- | Go to Step 14 | -- | ||||||
10 | The A/C system may contain too much moisture or air.
Are the instrument panel outlet air temperatures within the specified ranges of the A/C Performance Test Table? | -- | Go to Step 15 | Go to Step 11 | ||||||
11 | The A/C system may contain too much refrigerant oil.
Note: Operate the A/C system on low, in order to enhance oil flow to the high side of the system. Was more than the specified amount of refrigerant oil drained from the refrigerant desiccant tube? | 148 ml (5 oz) | Go to Step 12 | Go to Step 13 | ||||||
12 |
Are the actions complete? | -- | Go to Step 14 | -- | ||||||
13 |
Are the actions complete? | -- | Go to Step 14 | -- | ||||||
14 |
Are the high and low side pressures and instrument panel outlet air temperatures within specifications? | -- | Go to Step 15 | |||||||
15 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic. |