Step | Action | Normal Result(s) | Abnormal Result(s)* |
---|---|---|---|
1 | Visually inspect the battery hydrometer. | Battery hydrometer displays a green eye. | |
2 | Visually inspect battery cables. | Battery cables are clean and tightly connected. | Refer to Battery Cable . |
3 | Inspect IGNA Fuse 6, CRANK Fuse 8, GAUGES Fuse 4 and Fusible Link. | Fuses are not open. | Repair source of overload and replace Fuse. |
4 | Inspect all grounds. | All grounds are clean and tightly connected. | Clean and tighten grounds. |
5 | Inspect starter motor and starter solenoid. | Both starter motor and starter solenoid are properly mounted and starter solenoid terminals S and B are clean and tight. | Ensure proper mounting and clean and tighten terminals. |
6 | Inspect the generator. | Generator drive belt is tight. The generator connector and terminal are clean and tight. | Adjust Generator Drive Belt. Clean and tighten connectors and terminals. |
7 | Move the ignition switch from the OFF position to the RUN position. | BAT indicator lamp turns on, engine does not run. | Refer to Charge Indicator Inoperative . |
8 | Move the ignition switch to the START position and then slowly release. | Starter motor runs, the engine starts, and the BAT indicator lamp turns off. | Refer to Starter Solenoid Clicks, Engine Does Not Crank , Starter Solenoid Does Not Click , or Cooling Fan Inoperative - Auxiliary . |
9 | Allow engine to run for approximately 5-7 minutes. Measure voltage at the battery terminals. | Voltage reading of 13-16 volts. | Refer to Battery Load Test . |
* Refer to the appropriate symptom diagnostic table for the applicable abnormal result. |