Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Was the entire Lumbar Support System Check performed? | -- | ||||||
2 | Does the other lumbar support operate properly? | -- | ||||||
3 | Inspect the rear fuse block PWR SEAT circuit breaker for continuity. Is PWR SEAT circuit breaker OK? | -- | ||||||
4 | Replace the rear fuse block. Is the rear fuse block replacement complete? | -- | -- | |||||
5 | Repair the short to ground in CKT 3740 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
6 | Backprobe the lumbar switch connector with a DMM from cavity G (ORN) to ground. Is the voltage within the specified range? | 10-15 V | ||||||
7 | Backprobe the lumbar switch connector with a DMM from cavity G (ORN) to cavity E (BLK). Is the voltage within the specified range? | 10-15 V | ||||||
8 | Replace the lumbar switch. Refer to Lumbar Switch Replacement . Is the lumbar switch replacement complete? | -- | -- | |||||
9 | Repair the open in CKT 3740 (ORN) between S312 (LH) or S314 (RH) and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
10 | Perform the appropriate procedure:
Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Was the entire Lumbar Support System Check performed? | -- | ||||||
2 | Did the other adaptive seat operate properly? | -- | ||||||
3 | Inspect the rear fuse block MEM T&T Fuse for an open. Is MEM T&T Fuse OK? | -- | ||||||
4 | Inspect the rear fuse block IGN 3 RR Fuse for an open. Is IGN 3 RR Fuse OK? | -- | ||||||
5 | Replace the rear fuse block. Is the rear fuse block replacement complete? | -- | -- | |||||
6 | Repair the short to ground in CKT 2840 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
7 | Replace MEM T&T Fuse in the rear fuse block. Is MEM T&T Fuse replacement complete? | -- | -- | |||||
8 | Repair the short to ground in CKT 41 (BRN). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
9 | Replace IGN 3 RR Fuse in the rear fuse block. Is IGN 3 RR Fuse replacement complete? | -- | -- | |||||
10 | Backprobe the adaptive lumbar module connector with a DMM from cavity S (ORN) to ground. Is the voltage within the specified range? | 10-15 V | ||||||
11 | Backprobe the adaptive lumbar module connector with a DMM from cavity S (ORN) to cavity A (BLK). Is the voltage within the specified range? | 10-15 V | ||||||
12 |
Is the voltage within the specified range? | 10-15 V | ||||||
13 | Backprobe the lumbar switch connector with a DMM from cavity G (ORN) to ground. Is the voltage within the specified range? | 10-15 V | ||||||
14 |
Is the voltage within the specified range? | 10-15 V | ||||||
15 |
Is the voltage within the specified range? | 10-15 V | ||||||
16 |
Is the voltage within the specified range? | 10-15 V | ||||||
17 |
Is the voltage within the specified range? | 10-15 V | ||||||
18 |
Does the motor run? | -- | ||||||
19 |
Is the resistance less than the specified value? | 5 ohms | ||||||
20 | Connect a DMM from the lumbar pump motor connector cavity B (GRY) to ground. Is the resistance less than the specified value? | 5 ohms | ||||||
21 | Replace the adaptive lumbar module. Refer to Lumbar Component Replacement - Power . Is the adaptive lumbar module replacement complete? | -- | -- | |||||
22 | Repair the open in CKT 2840 (ORN) between S302 and the adaptive lumbar module. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
23 | Perform the appropriate procedure:
Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
24 | Repair the open in CKT 41 (BRN) between the rear fuse block and the adaptive lumbar module. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
25 |
Is the resistance less than the specified value? | 5 ohms | ||||||
26 | Connect a DMM from the lumbar switch connector cavity G (ORN) to the adaptive lumbar module connector cavity L (ORN). Is the resistance less than the specified value? | 5 ohms | ||||||
27 | Repair the short to ground in CKT 1740 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
28 | Repair the open in CKT 1740 (ORN) between the adaptive lumbar module and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
29 |
Is the resistance less than the specified value? | 5 ohms | ||||||
30 | Connect a DMM from the lumbar switch connector cavity B (PNK) (LH) or cavity C (LT BLU/WHT) (RH) to the adaptive lumbar module connector cavity F. Is the resistance less than the specified value? | 5 ohms | ||||||
31 | Repair the short to ground in CKT 2290 (PNK) (LH) or CKT 2292 (LT BLU/WHT) (RH). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
32 | Repair the open in CKT 2291 (WHT) (LH) or CKT 2293 (PPL) (RH) between the adaptive lumbar module and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
33 |
Is the resistance less than the specified value? | 5 ohms | ||||||
34 | Connect a DMM from the lumbar switch connector cavity C (WHT) (LH) or cavity B (PPL) (RH) to the adaptive lumbar module connector cavity E. Is the resistance less than the specified value? | 5 ohms | ||||||
35 | Repair the short to ground in CKT 2291 (WHT) (LH) or CKT 2293 (PPL). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
36 | Repair the open in CKT 2291 (WHT) (LH) or CKT 2293 (PPL) (RH) between the adaptive lumbar module and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
37 |
Is the resistance less than the specified value? | 5 ohms | ||||||
38 | Connect a DMM from the lumbar switch connector cavity A (DK BLU) (LH) or (WHT) (RH) to the adaptive lumbar module connector cavity G. Is the resistance less than the specified value? | 5 ohms | ||||||
39 | Repair the short to ground in CKT 1064 (DK BLU) (LH) or CKT 210 (WHT) (RH). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
40 | Repair the open in CKT 1064 (DK BLU) (LH) or CKT 210 (WHT) (RH) between the adaptive lumbar module and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
41 |
Is the resistance less than the specified value? | 5 ohms | ||||||
42 | Connect a DMM from the lumbar switch connector cavity F (YEL) (LH) or (DK BLU) (RH) to the adaptive lumbar module connector cavity H. Is the resistance less than the specified value? | 5 ohms | ||||||
43 | Repair the short to ground in CKT 1065 (YEL) (LH) or CKT 211 (DK BLU). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
44 | Repair the open in CKT 1065 (YEL) (LH) or CKT 211 (DK BLU) (RH) between the adaptive lumbar module and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
45 |
Is the voltage within the specified range? | 10-15 V | ||||||
46 | Replace the lumbar pump motor. Refer to Lumbar Component Replacement - Power . Is the motor replacement complete? | -- | -- | |||||
47 | Repair the open in CKT 9172 (BRN) between the adaptive lumbar module and the lumbar pump motor. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
48 | Repair the open in CKT 9173 (GRY) between the adaptive lumbar module and the lumbar pump motor. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |||||
49 | Replace the lumbar switch. Refer to Lumbar Switch Replacement . Is the lumbar switch replacement complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the entire Lumbar Support System Check performed? | -- | ||
2 | Inspect the rear fuse block MEM T&T Fuse for an open. Is MEM T&T Fuse OK? | -- | ||
3 | Repair the short to ground in CKT 2840 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |
4 | Replace the MEM T&T Fuse. Is the fuse replacement complete? | -- | -- | |
5 |
Is the voltage within the specified range? | 10-15 V | ||
6 | Connect a DMM from the lumbar switch cavity G (ORN) to cavity E (BLK). Is the voltage within the specified range? | 10-15 V | ||
7 | Does the lumbar move when a memory recall function is performed? | -- | ||
8 | Replace the lumbar switch. Refer to Lumbar Switch Replacement . Is the LH switch replacement complete? | -- | -- | |
9 | Replace the memory seat module (MSM). Refer to Memory Seat Control Module Replacement . Is the MSM replacement complete? | -- | -- | |
10 | Repair the open in CKT 2840 (ORN) between S326 and the lumbar switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- | |
11 | Repair the open in CKT 550 (BLK) (RH drive) or CKT 650 (BLK) (LH drive) between S313 and the LH seat switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | -- |