GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

    Caution: Before servicing any electrical component, the ignition and start switch must be in the OFF or LOCK position and all electrical loads must be OFF, unless instructed otherwise in these procedures. If a tool or equipment could easily come in contact with a live exposed electrical terminal, also disconnect the negative battery cable. Failure to follow these precautions may cause personal injury and/or damage to the vehicle or its components.

  1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
  2. Remove the intake air resonator. Refer to Intake Air Resonator Replacement in Engine Controls - 3.0L (L81).
  3. Remove the drive belt. Refer to Drive Belt Replacement in Engine Mechanical  - 3.0L (L81).
  4. Raise and support the vehicle. Refer to Lifting and Jacking the Vehicle in General Information.
  5. Remove the generator cooling duct from the generator cooling duct cap.

  6. Object Number: 217393  Size: SH
  7. Remove the field coil terminal nut (1) from the generator.
  8. Remove the field coil terminal lead from the generator.
  9. Remove the positive battery cable nut (2) from the generator.
  10. Remove the positive battery cable from the generator.

  11. Object Number: 217395  Size: SH
  12. Remove the generator upper mounting nut (4).
  13. Remove the generator lower mounting nut.
  14. Remove the generator through bolts (1,2).
  15. Lower the vehicle.
  16. Remove the generator (3).
  17. Remove the generator cooling duct cap screws.
  18. Remove the generator cooling duct cap.

Installation Procedure

  1. Install the generator cooling duct cap.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the generator cooling duct cap screws.
  4. Tighten
    Tighten the generator cooling duct screws to 1 N·m (9 lb in).


    Object Number: 217395  Size: SH
  5. Position the generator (3) in the mounting position.
  6. Raise the vehicle.
  7. Install the generator through bolts (1,2).
  8. Install the generator lower mounting nut.
  9. Tighten
    Tighten the generator lower mounting nut to 40 N·m (30 lb ft).

  10. Install the generator upper mounting nut (4).
  11. Tighten
    Tighten the generator upper mounting nut (4) to 40 N·m (30 lb ft).


    Object Number: 217393  Size: SH
  12. Install the positive battery cable to the generator.
  13. Install the positive battery cable nut (2) to the generator.
  14. Tighten
    Tighten the positive battery cable nut (2) to 8 N·m (71 lb in).

  15. Install the field coil terminal lead to the generator.
  16. Install the field coil terminal lead nut (1) to the generator.
  17. Tighten
    Tighten the field coil terminal lead nut (1) to 3.5 N·m (31 lb in).

  18. Install the generator cooling duct to the generator cooling duct cap.
  19. Lower the vehicle.
  20. Install the drive belt. Refer to Drive Belt Replacement in Engine Mechanical  - 3.0L (L81).
  21. Install the intake air resonator. Refer to Intake Air Resonator Replacement in Engine Controls - 3.0L (L81).
  22. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .