Front Side Door Window Regulator Replacement Power Regulator
Removal Procedure
- Remove the door trim panel.
Refer to
Door Trim Panel Replacement
.
- Remove the water deflector in order to access the window regulator.
Refer to
Door Water Deflector Replacement
.
- Remove the window assembly. Refer to
Door Window Replacement
.
- Remove the power window regulator bolts (3).
- Remove the power window regulator rivets (2).
- Remove the power window regulator (5).
Installation Procedure
- Install the power window
regulator (5).
- Install the power window regulator rivets (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the power
window regulator bolts (3).
Tighten
Tighten the bolts (3) to 10 N·m (89 lb in).
- Install the power window regulator nuts (4).
Tighten
Tighten the nuts (4) to 10 N·m (89 lb in).
- Install the window assembly. Refer to
Door Window Replacement
.
- Install the water deflector. Refer to
Door Water Deflector Replacement
.
- Install the door trim panel. Refer to
Door Trim Panel Replacement
.
Front Side Door Window Regulator Replacement Manual Regulator
Removal Procedure
- Remove the door trim panel.
Refer to
Door Trim Panel Replacement
.
- Remove the water deflector in order to access the window regulator.
Refer to
Door Water Deflector Replacement
.
- Remove the window assembly. Refer to
Door Window Replacement
.
- Remove the manual window regulator bolts (3).
- Remove the manual window regulator rivets (2).
- Remove the manual window regulator (5).
Installation Procedure
- Install the manual window
regulator (5).
- Install the manual window regulator rivets (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the manual
window regulator bolts (3).
Tighten
Tighten the bolts (3) to 10 N·m (89 lb in).
- Install the manual window regulator nuts (4).
Tighten
Tighten the nuts (4) to 10 N·m (89 lb in).
- Install the window assembly. Refer to
Door Window Replacement
.
- Install the water deflector. Refer to
Door Water Deflector Replacement
.
- Install the door trim panel. Refer to
Door Trim Panel Replacement
.