Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 |
Is the measured voltage less than the indicated value? | 0.5 V | Go to Step 2 | Go to Step 5 | ||||
2 |
Is the measured voltage less than the indicated value? | 0.5 V | Go to Step 3 | Go to Step 6 | ||||
3 | Connect a remote starter switch between the starter solenoid terminal S and the battery positive terminal. Does the starter crank? | -- | Go to Step 4 | Go to Step 7 | ||||
4 | Repair the high resistance or the poor connection in starter circuit. Has the repair been made and the system rechecked? | -- | Refer to Starting System Check | -- | ||||
5 | Replace the battery positive cable.
Has the repair been made and the system rechecked? | -- | Refer to Starting System Check | -- | ||||
6 | Replace the battery negative cable.
Has the repair been made and the system rechecked? | -- | Refer to Starting System Check | -- | ||||
7 | Replace the starter.
Has the repair been made and the system rechecked? | -- | Refer to Starting System Check | -- |