GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Lower the door window to the full down position.
  2. Remove the door trim panel. Refer to Front Side Door Trim Panel Replacement .
  3. Remove the rearward half of the water deflector. Refer to Front Side Door Water Deflector Replacement .
  4. Remove the window inner belt seal. Refer to Front Side Door Window Belt Inner Sealing Strip Replacement .

  5. Object Number: 441943  Size: SH
  6. Pull the lower rear portion of the window seal out of the door frame far enough to gain access to the lower fastener of the door frame applique.

  7. Object Number: 441807  Size: SH
  8. Remove the upper run channel fastener (1), which is also the lower door applique fastener.
  9. Reinstall the window weatherstrip into the door frame.
  10. Connect the door trim panel wire connector.
  11. Run the window up until there is a one inch opening at the top.
  12. Remove the lower run channel fastener (2).
  13. Pull the run channel down to clear the window.
  14. Remove the run channel.

Installation Procedure


    Object Number: 441807  Size: SH
  1. Insert the run channel into the door through the front access hole.
  2. Slide the run channel up along the window , making sure the upper portion is under the door frame applique and the water shield is against the rearward surface of the inner door panel above the latch.
  3. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the lower fastener (2).
  5. Tighten
    Tighten the lower fastener to 9 N·m (80 lb in).


    Object Number: 441943  Size: SH
  6. Lower the window to the full down position.
  7. Pull out enough of the lower rear edge of the window seal to install the upper fastener in the run channel and door applique.
  8. Install the fastener.
  9. Tighten
    Tighten the fastener to 2 N·m (18 lb in).


    Object Number: 489783  Size: SH

    Important: When reusing the window weatherstrip, the flange mounting area (1) must be pinched together to counteract the splaying effect when removed. Use thumb and index finger to pinch the carrier (2) back together. Work from one end of the weatherstrip to the other.

  10. Reinstall the window weatherstrip into the door frame.
  11. Install the window inner belt seal. Refer to Front Side Door Window Belt Inner Sealing Strip Replacement .
  12. Install the water deflector. Refer to Front Side Door Water Deflector Replacement .
  13. Install the door trim panel. Refer to Front Side Door Trim Panel Replacement .