DEFINITION: Air does not flow correctly from the air distribution outlets.

1

Did you perform the HVAC Diagnostic System Check?

Go to Step 2

Go to Diagnostic System Check - HVAC Systems - Automatic

2

  1. Turn ON the ignition, with the engine OFF.
  2. Turn OFF the HVAC controls.

Is the blower motor OFF

Go to Step 3

Go to Blower Motor Always On

3

Place the blower motor switch in each speed position.

Does the blower motor operate in any of the speed positions?

Go to Step 4

Go to Blower Motor Inoperative

4

Does the blower motor operate at the desired speed in each speed position?

Go to Step 5

Go to Blower Motor Malfunction

5

  1. Place the blower motor switch in the maximum speed position.
  2. Place the mode switch in the bi-level position.
  3. Place recirculation switch in the outside air and recirculation positions.

Does the recirculation door move from the recirculation position to the outside air position?

Go to Step 6

Go to Air Recirculation Malfunction

6

  1. Install a scan tool.
  2. With a scan tool, perform the Recalibrate all Motors command in Instrument Panel Module Special Functions.
  3. With a scan tool, observe the current DTC list in Instrument Panel Module.

Does the scan tool display any DTCs?

Go to Diagnostic Trouble Code (DTC) List

Go to Step 7

7

Place the mode switch in each position.

Does the display on the HVAC control module respond correctly to changes in mode selection?

Go to Step 8

Go to Step 14

8

Place the mode switch in each position.

Does the air flow from the correct air distribution outlets in each mode position?

Go Testing for Intermittent Conditions and Poor Connections in Wiring Systems

Go to Step 9

9

  1. With a scan tool, observe the HTR/DEF/AC Dr Commanded parameter in the Instrument Panel Module data list.
  2. Place the mode switch in each position.

Does the scan tool indicate that the HTR/DEF/AC Dr Commanded parameter changes for each change in selected mode position?

Go to Step 10

Go to Step 15

10

Test the ignition 3 voltage circuit and the low reference circuit of the mode actuator for high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 18

Go to Step 11

11

Inspect the air delivery system for the following conditions:

    • A dirty HVAC filter (if applicable)
    • An obstruction to the air flow
    • Air leaks.
    • Misaligned air ducts.

Did you find and correct the condition?

Go to Step 18

Go to Step 12

12

Inspect the mode door and the mode actuator for the following conditions:

    • Misaligned actuator door. Refer to Mode Actuator Replacement
    • Broken or binding linkages or mode door
    • Obstruction that prevents the mode actuator from operating within it's full range of motion
    • Missing seals to the mode door
    • Misaligned seals to the mode door

Did you find and correct the condition?

Go to Step 19

Go to Step 13

13

Inspect for poor connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 19

Go to Step 16

14

Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 19

Go to Step 17

15

Inspect for poor connections at the harness connector of the instrument panel integration module (IPM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 19

Go to Step 18

16

Important: Perform the recalibration procedure for the mode actuator.

Replace the mode actuator. Refer to Mode Actuator Replacement .

Did you complete the replacement?

Go to Step 19

--

17

Replace the HVAC control module. Refer to HVAC Control Module Replacement .

Did you complete the replacement?

Go to Step 19

--

18

Important: Perform the recalibration procedure for the instrument panel integration module (IPM).

Replace the instrument panel integration module (IPM). Refer to Instrument Panel Module Replacement in Body Control System.

Did you complete the replacement?

Go to Step 19

--

19

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 2