The number(s) below refer to the step number(s) on the diagnostic table.
This step tests for blower motor operation in any speed setting.
This step determines if the instrument panel integration module (IPM) is receiving a blower speed request from the HVAC control module and commanding an output.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor is inoperative in all speed positions. | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
Does the blower motor operate in the desired speed(s)? | -- | Go to Blower Motor Malfunction | Go to Step 3 | |
Does the scan tool indicate that the Commanded Blower parameter is near the specified value? | 100% | Go to Step 5 | Go to Step 4 | |
4 |
Does the scan tool indicate that the Commanded Blower parameter is near the specified value? | 100% | Go to Step 13 | Go to Step 14 |
5 |
Does the test lamp illuminate? | -- | Go to Step 11 | Go to Step 6 |
6 | Test the battery positive voltage circuit of the blower motor control processor for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 7 |
7 | Test the ground circuit of the blower motor control processor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 8 |
8 |
Important: Ensure that the blower motor control processor module and the IPM control assembly connectors are connected during this step in order to avoid misdiagnosis.
Does the voltage measure near the specified values for each commanded state? | 5.0 V OFF 1.5 V ON | Go to Step 12 | Go to Step 9 |
9 |
Does the voltage measure near the specified value? | 5.0 V | Go to Step 14 | Go to Step 10 |
10 | Test the blower motor speed control circuit of the instrument panel integration module (IPM) for an open, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 12 |
11 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 15 |
12 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 16 |
13 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 17 |
14 | Inspect for poor connections at the harness connector of the instrument panel integration module (IPM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 18 |
15 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | -- | Go to Step 19 | -- |
16 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | -- | Go to Step 19 | -- |
17 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 19 | -- |
18 |
Important: Perform the recalibration procedure for the instrument panel integration module (IPM). Replace the instrument panel integration module (IPM). Refer to Instrument Panel Module Replacement in Body Control System. Did you complete the replacement? | -- | Go to Step 19 | -- |
19 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |