Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: This test checks the condition of the inflator timer-relay and the surrounding circuits. | ||||||||||
1 |
Does the air compressor operate and then stop? | -- | Go to Step 2 | |||||||
2 |
Is battery voltage present? | B+ | Go to Step 4 | Go to Step 3 | ||||||
3 | Repair the open circuit condition in one of the following circuits/components:
Is the repair or replacement complete? | -- | -- | |||||||
4 | Measure the voltage at connector (harness side) terminal D. Is battery voltage present? | B+ | Go to Step 6 | Go to Step 5 | ||||||
5 | Repair the open circuit condition in CKT 1042 (RED) between the inflator timer relay and the RH MaxiFuse® block. Is the repair complete? | -- | -- | |||||||
6 | Check for continuity between the connector (harness side) terminal H and ground. Is continuity present? | -- | Go to Step 8 | Go to Step 7 | ||||||
7 | Repair the open circuit condition in CKT 1250 (BLK). Is the repair complete? | -- | -- | |||||||
8 |
Is continuity present? | -- | Go to Step 9 | Go to Inflator Switch Test | ||||||
9 |
Is continuity present? | -- | Go to Step 10 | Go to Inflator Switch Test | ||||||
10 | Replace the inflator timer-relay. Is the replacement complete? | -- |