Step

Action

Value(s)

Yes

No

DEFINITION: This test checks the condition of the inflator timer-relay and the surrounding circuits.

1

  1. Turn the ignition ON.
  2. Put the inflator switch in the ON position.
  3. Put the inflator switch in the OFF position.

Does the air compressor operate and then stop?

--

Go to Inflator Solenoid Valve Test

Go to Step 2

2

  1. Disconnect the connector from the inflator timer-relay.
  2. Measure the voltage at connector (harness side) terminal E.

Is battery voltage present?

B+

Go to Step 4

Go to Step 3

3

Repair the open circuit condition in one of the following circuits/components:

    • CKT 321 (YEL) between the inflator timer-relay and the IP junction block
    • ELC relay
    • CKT 641 (BRN) from the IP junction block to the IP fuse block

Is the repair or replacement complete?

--

Go to Automatic Level Control System Operation Check

--

4

Measure the voltage at connector (harness side) terminal D.

Is battery voltage present?

B+

Go to Step 6

Go to Step 5

5

Repair the open circuit condition in CKT 1042 (RED) between the inflator timer relay and the RH MaxiFuse® block.

Is the repair complete?

--

Go to Automatic Level Control System Operation Check

--

6

Check for continuity between the connector (harness side) terminal H and ground.

Is continuity present?

--

Go to Step 8

Go to Step 7

7

Repair the open circuit condition in CKT 1250 (BLK).

Is the repair complete?

--

Go to Automatic Level Control System Operation Check

--

8

  1. Hold the inflator switch in the OFF position.
  2. Check for continuity between the connector (harness side) terminal A and ground.

Is continuity present?

--

Go to Step 9

Go to Inflator Switch Test

9

  1. Hold the inflator switch in the ON position.
  2. Check for continuity between the connector (harness side) terminal F and ground.

Is continuity present?

--

Go to Step 10

Go to Inflator Switch Test

10

Replace the inflator timer-relay.

Is the replacement complete?

 