Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: This test checks the inflator switch and the surrounding circuits. | ||||
1 |
Is the measurement approximately 0 ohms? | ohms | Go to Step 5 | Go to Step 2 |
2 | Check the inflator switch connector for proper terminal contact at terminals A and B. Is the connection OK? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the inflator switch. Is the replacement complete? | -- | -- | |
4 | Correct the poor connection condition. Is the connection at the inflator switch good? | -- | -- | |
5 | Measure the resistance from inflator switch connector terminal C to B. Is the measurement approximately 0 ohms? | ohms | Go to Step 6 | Go to Step 8 |
6 | Check CKT 837 (WHT), CKT 1267 (PPL) and CKT 1250 (BLK) wiring for an open. Is an open circuit condition present? | -- | Go to Step 7 | |
7 | Repair the open circuit condition. Is the repair complete? | -- | -- | |
8 | Check the inflator switch connector for proper terminal contact at terminals C and B. Are the connections good? | -- | Go to Step 9 | Go to Step 10 |
9 | Replace the inflator switch. Is the replacement complete? | -- | -- | |
10 | Correct the poor connection condition. Is the connection of the inflator switch connection good? | -- | -- |