Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Backup Lights System Check? | -- | Go to Backup Lamp System Check | |
2 |
Is the voltage within the specified range? | 10-15 V | ||
3 | Connect a DMM from the suspect backup lamp connector cavity A (LT GRN) to cavity G (BLK). Is the voltage within specified range? | 10-15 V | ||
4 | Replace the suspect backup lamp. Refer to one of the following procedures: Is the repair complete? | -- | Go to Backup Lamp System Check | -- |
5 | Repair the open in CKT 24 (LT GRN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Backup Lamp System Check | -- |
6 | Repair the open in CKT 1350 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Backup Lamp System Check | -- |