GM Service Manual Online
For 1990-2009 cars only

Step

Action

Values

Yes

No

Schematic Reference: HVAC Schematics

DEFINITION: The blower motor is inoperative in all speed positions.

1

Did you perform the HVAC Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - HVAC Systems - Automatic

2

  1. Turn ON the ignition, with the engine OFF.
  2. Place the blower switch in each speed position.

Does the blower motor operate in any speed position?

--

Go to Blower Motor Malfunction

Go to Step 3

3

  1. Place the blower switch in the maximum speed position.
  2. With the scan tool observe the Desired Blower Mtr Speed parameter in the Heating and Air Conditioning data list.

Does the scan tool indicate that the Desired Blower Mtr Speed parameter is near the specified value?

111 counts

Go to Step 4

Go to Step 12

4

  1. Turn OFF the ignition.
  2. Disconnect the blower motor connector.
  3. Turn ON the ignition, with the engine OFF.
  4. Connect a test lamp between the blower motor supply voltage circuit and the blower motor control circuit.
  5. Place the blower switch in the minimum speed position.

Does the test lamp illuminate?

--

Go to Step 10

Go to Step 5

5

Test the battery positive voltage circuit of the blower motor control processor for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 6

6

Test the ground circuit of the blower motor control processor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 7

7

Important: The blower motor control processor connector and the HVAC control module connectors must be connected to correctly perform the test.

  1. Backprobe and measure the voltage from the blower speed control circuit at the HVAC control module to a good ground.
  2. With a scan tool, command the blower motor OFF and ON.

Does the voltage measure near the specified values for each commanded state?

5.0 V OFF

1.0 V ON

Go to Step 11

Go to Step 8

8

  1. Turn the ignition OFF.
  2. Disconnect the HVAC control module.
  3. Turn ON the ignition, with the engine OFF.
  4. Measure the voltage from the blower speed control circuit of the HVAC control module to a good ground.

Does the voltage measure near the specified value?

5.0 V

Go to Step 12

Go to Step 9

9

Test the blower speed control circuit of the HVAC control module for an open, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

 

Go to Step 16

Go to Step 11

10

Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 13

11

Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 14

12

Inspect for poor connections at the harness connector of the HVAC control module . Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 15

13

Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

--

Go to Step 16

--

14

Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement .

Did you complete the replacement?

--

Go to Step 16

--

15

Important: Perform the recalibration procedure for the HVAC control module.

Replace the HVAC control module. Refer to HVAC Control Module Replacement in Body Control System.

Did you complete the replacement?

--

Go to Step 16

--

16

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 2