Important: The opening to the blower motor control processor is slotted. Access to the blower motor control processor opening is limited.
Important: Tilt down the rear of the blower motor control processor.
Important: Align the blower motor control processor forward retaining slots onto screws and seat the blower motor control processor against the HVAC module.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the blower motor control processor rearward screws to 1.5 N·m
(13 lb in).
Tighten
Tighten the blower motor control processor forward screws to 1.5 N·m
(13 lb in).