Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
Is the airflow high? | -- | Go to Step 2 | G to Step 20 | ||||||||
2 | Inspect the blower speeds for a change in the airflow. Does the speed of the airflow change? | -- | Go to Step 3 | |||||||||
3 |
Caution: The cooling system is pressurized when hot. Is the heater temperature low according to the chart? | -- | Go to Step 5 | Go to Step 4 | ||||||||
4 |
Does the problem persist? | -- | Go to Step 5 | System OK | ||||||||
5 |
Does the temperature valve appear to be operating? | -- | Go to Step 6 | Go to Step 17 | ||||||||
6 | Verify the temperature valve operation. Is the temperature valve operating? | -- | Go to Step 8 | Go to Step 7 | ||||||||
7 | Inspect for the following conditions. Repair the components as needed.
Does the problem persist? | -- | Go to Step 8 | System OK | ||||||||
8 |
Are both hoses warm? | -- | Go to Step 9 | Go to Step 12 | ||||||||
9 | Inspect the thermostat for the following conditions:
Is the installation OK? | -- | Go to Step 10 | Go to Step 11 | ||||||||
10 | Replace the thermostat. Refer to Engine Coolant Thermostat Replacement . Is the repair complete? | -- | System OK | -- | ||||||||
11 | Reinstall the thermostat. Refer to Engine Coolant Thermostat Replacement . Verify proper installation. Is the repair complete? | -- | System OK | -- | ||||||||
12 | Ensure that the outlet hose is hot and the inlet hose is warm.
Are the hoses installed in reverse? | -- | Go to Step 13 | Go to Step 14 | ||||||||
13 |
Does the problem persist? | -- | Go to Step 14 | System OK | ||||||||
14 |
Are both hoses warm? | -- | Go to Step 15 | Go to Step 16 | ||||||||
15 | Replace the heater core. Refer to Heater Core Replacement . Is the repair complete? | -- | System OK | -- | ||||||||
16 | Ensure that the outlet hose is hot and the inlet hose is warm. Is the inlet hose hot and the outlet hose warm? | -- | System OK | -- | ||||||||
17 | Inspect the connection to the temperature valve actuator. Is the temperature valve actuator connected? | -- | Go to Step 19 | Go to Step 18 | ||||||||
18 | Connect the temperature valve actuator. Verify proper operation of the system. Is the system operating properly? | -- | System OK | -- | ||||||||
19 | Inspect the following components:
Repair or replace the components as needed. Is the system operating properly? | -- | System OK | -- | ||||||||
20 | The airflow is low or nonexistent. Perform the HVAC functional inspection. Refer to VDOT Air Conditioning (A/C) System Diagnosis . Does the problem persist? | -- | Go to Step 21 | System OK | ||||||||
21 | Inspect the airflow out of the defroster outlets or the vent outlets. Is the airflow out of the defroster outlets or the vent outlets high? | -- | Go to Step 22 | Go to Step 23 | ||||||||
22 | Inspect the system for the following conditions:
Repair or replace the valves as needed. Refer to Floor Air Outlet Replacement . Is the repair complete? | -- | System OK | -- | ||||||||
23 | The airflow out of the defroster outlets or the vent outlets is low or nonexistent.
Is the defroster airflow OK? | -- | Go to Step 24 | Go to Step 25 | ||||||||
24 |
Does the system operate properly? | -- | System OK | -- | ||||||||
25 | Inspect the blower speeds for airflow changes. Are the speed changes OK? | -- | Go to Step 26 | Go to Electrical Diagnosis | ||||||||
26 | Inspect the system for obstructions at the blower inlet and the plenum. Were any obstructions found? | -- | Go to Step 27 | Go to Step 28 | ||||||||
27 | Remove the obstructions as needed. Does the system operate properly? | -- | System OK | -- | ||||||||
28 |
Did a change in the airflow occur? | -- | Go to Step 29 | Go to Step 30 | ||||||||
29 | Inspect the system for an obstruction between the blower and the system outlets. Remove any obstruction as needed. Does the system operate properly? | -- | System OK | -- | ||||||||
30 | Inspect the temperature valve and the actuator for proper operation. Repair the components as needed. Does the system operate properly? | -- | System OK | -- |