• | Transmission control module (TCM) detects that analog-to-digital (A/D) value of transmission fluid temperature (TFT) sensor signal is less than 15 and the minimum A/D value is more than 943, when it is past 15 minutes after ignition ON--A/D value 943:4.7 V |
• | After 1 occurrence of above detection |
• | Gear selector position is except P and N |
• | Engine revolution is 400 RPM or greater |
• | TCM will request the illumination of the hold lamp and store the DTC when the TCM detects a failures on the first ignition cycle. |
• | TCM judges the temperature of the transmission fluid is 200°C (392°F) |
• | No lockup control |
• | No 4th gear |
• | No self-learning control |
• | No timing solenoid control N-D |
• | The TCM turns off the hold lamp when no further failures are detected on the next ignition cycles. |
• | The scan tool can clear the DTC from the TCM history. |
• | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. |
• | The TCM detects the temperature of the transmission fluid is between 0°C and 150°C for 10 seconds continuously. |
• | Wiring harness or connector between TFT sensor and TCM |
• | TFT sensor |
• | TCM |
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 |
Is the hold lamp ON? | -- | Go to Step 2 | Go to Step 4 |
2 |
Is DTC P0713 displayed? | -- | Go to Step 3 | Go to Step 4 |
3 |
Is the measurement within the specified range? | 10°C (50°F) 5.80-7.09K ohms 110°C (230°F) 0.231-0.263K ohms | Go to Step 5 | Go to Step 6 |
4 | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair? | -- | System OK | -- |
5 |
Is the connection condition OK? | -- | Go to Step 7 | Go to Step 4 |
6 |
Is the measurement within the specified range? | 10°C (50°F) 5.80-7.09K ohms 110°C (230°F) 0.231-0.263K ohms | Go to Step 8 | Go to Step 9 |
7 |
Is DTC displayed? | -- | Go to Step 1 | System OK |
8 |
Is the condition OK? | -- | System OK | Go to Step 4 |
9 |
Is the problem found? | -- | Go to Step 11 | Go to Step 10 |
10 |
Is the condition OK? | -- | System OK | Go to Step 4 |
11 | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Inspection Did you complete the repair? | -- | System OK | -- |
• | Transmission control module (TCM) detects that analog-to-digital (A/D) value of transmission fluid temperature (TFT) sensor signal is less than 15 and the minimum A/D value is more than 943, when it is past 15 minutes after ignition ON--A/D value 943:4.7 V |
• | After 1 occurrence of above detection |
• | Gear selector position is except P and N |
• | Engine revolution is 400 RPM or greater |
• | TCM will request the illumination of the malfunction indicator lamp (MIL) and store the DTC when the TCM detects a failures on the first ignition cycle. |
• | TCM judges the temperature of the transmission fluid is 200°C (392°F) |
• | No lockup control |
• | No 4th gear |
• | No self-learning control |
• | No timing solenoid control N-D |
• | The TCM turns off the MIL lamp when no further failures are detected on the next ignition cycles. |
• | The scan tool can clear the DTC from the TCM history. |
• | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. |
• | The TCM detects the temperature of the transmission fluid is between 0°C and 150°C for 10 seconds continuously. |
• | Wiring harness or connector between TFT sensor and TCM |
• | TFT sensor |
• | TCM |
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 |
Is the malfunction indicator lamp (MIL) ON? | -- | Go to Step 2 | Go to Step 4 |
2 |
Is DTC P0713 displayed? | -- | Go to Step 3 | Go to Step 4 |
3 |
Is the measurement within the specified range? | 10°C (50°F) 5.80-7.09K ohms 110°C (230°F) 0.231-0.263K ohms | Go to Step 5 | Go to Step 6 |
4 | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair? | -- | System OK | -- |
5 |
Is the connection condition OK? | -- | Go to Step 7 | Go to Step 4 |
6 |
Is the measurement within the specified range? | 10°C (50°F) 5.80-7.09K ohms 110°C (230°F) 0.231-0.263K ohms | Go to Step 8 | Go to Step 9 |
7 |
Is DTC displayed? | -- | Go to Step 1 | System OK |
8 |
Is the condition OK? | -- | System OK | Go to Step 4 |
9 |
Is the problem found? | -- | Go to Step 11 | Go to Step 10 |
10 |
Is the condition OK? | -- | System OK | Go to Step 4 |
11 | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Inspection Did you complete the repair? | -- | System OK | -- |