Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Did you perform the Interior Lights System Check? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 5 |
3 | Inspect for a short to ground in the RED/GRN wire between the illumination controller and the illumination lamps. Is the connection OK? | -- | Go to Step 4 | Go to Step 6 |
4 | Replace the illumination controller. Refer to Instrument Panel Lamp Dimmer Switch Replacement in Instrument Panel,Gauges and Console. Is the repair complete? | -- | -- | |
5 | Repair the open in the RED/YEL wire between S218 and the illumination controller. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Repair the short to ground in the RED/GRN wire between the illumination controller and the illumination lamps. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |