• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Oil Pressure Switch Signal | 1 | P0520 | 1 | -- |
Low Reference | -- | P0520 | 1 | -- |
1. Engine Oil Pressure Indicator Malfunction |
The engine oil pressure (EOP) switch is a normally closed switch that opens with the proper oil pressure. With the ignition switch turned ON and the engine not running, the engine control module (ECM) should detect a low signal voltage input. With the engine running, the pressure switch opens, and the ECM should detect a high signal voltage input. When the oil pressure is low, the ECM sends a serial data message to the body control module (BCM) requesting the EOP indicator turned ON. The instrument panel cluster (IPC) illuminates the EOP indicator when the IPC receives a serial data message from the BCM requesting the EOP indicator turned ON.
Control Module References for scan tool information
Ignition ON, engine running, verify the scan tool Engine Oil Pressure Switch parameter is OK.
⇒ | If not the specified value, refer to: |
• | Oil Pressure Diagnosis and Testing for the 3.6L engine. |
• | Oil Pressure Diagnosis and Testing for the 2.4L engine. |
⇒ | If greater than the specified value, test the circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Engine Oil Pressure Sensor and/or Switch Replacement for the 3.6L engine |
• | Engine Oil Pressure Sensor and/or Switch Replacement for the 2.4L engine |
• | Control Module References for the ECM and IPC replacement, setup, and programming |
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Engine Oil Pressure 5-Volt Reference | P0522 | 1 | P0522 | P0523 | P0521 |
Engine Oil Pressure Sensor Signal | P0522 | 1 | P0522 | P0523 | P0521 |
Low Reference | -- | 1 | P0523 | -- | P0521 |
1. Engine Oil Pressure Indicator Malfunction |
The engine oil pressure (EOP) sensor changes voltage based on the engine oil pressure. The EOP sensor is a 3-wire sensor comprising of the signal circuit, the low reference circuit and the 5-volt reference circuit. The engine control module (ECM) supplies 5-volts to the EOP sensor via the 5-volt reference circuit and provides ground via the EOP low reference circuit. The ECM monitors the signal circuit of the EOP sensor to determine the engine oil pressure sensor voltage is within the normal operating range of approximately 1-4 volts. When the engine oil pressure is high, the EOP sensor voltage is high and the ECM senses a high signal voltage. When the engine oil pressure is low, the EOP sensor voltage is low and the ECM senses a low signal voltage. The ECM sends the EOP information to the instrument panel cluster (IPC) via the serial data circuit.
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit terminal 3 for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the EOP indicator does not turn OFF, replace the IPC. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for the PCM or IPC replacement, setup, and programming |