• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Brake pedal position sensor circuit | C0277 06 | C0277 06 | C0277 07 | C0277 09 C0277 4B |
Brake pedal position sensor 5-volt reference | C0890 03 | C0890 03 | C0890 07 | C0890 03 C0890 07 |
Brake pedal position sensor low reference | C0890 03 | C0890 03 | C0890 07 | C0890 03 C0890 07 |
The body control module (BCM) applies a ground through the brake pedal position sensor (BPPS) low reference circuit to the BPPS. The BCM supplies a 5-volt reference through the brake sensor reference voltage circuit to the BPPS. When the brake pedal is being applied, the BPPS then sends a variable voltage through the brake sensor signal circuit to the BCM.
The ignition is ON.
The BCM detects an open or a short to ground on the BPPS circuit.
The BCM detects short to voltage on the BPPS circuit.
The BCM detects the BPPS reading is erroneous.
The BCM detect that the BPPS is not calibrated.
The BCM detects a voltage that is lower then 5 volts on the BPPS 5-volt reference circuit.
The BCM detects a voltage that is greater then 5 volts on the BPPS 5-volt reference circuit.
The stop lamps will not function correctly.
The BCM clears these codes from current when the fault is removed from the system.
If DTC C0277 4B is set, perform the BPPS calibration. If the DTC resets, then perform the circuit/system testing.
Lighting Systems Connector End Views
Ignition ON, press and release the brake pedal. The stop lamps should illuminate then go out.
⇒ | If less then 4.7 volts, test the BPPS 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit/connections test normal, replace the BCM. |
⇒ | If greater than 5.2 volts, test the BPPS 5-volt reference circuit for a short to voltage. If the circuit/connections test normal, replace the BCM. |
⇒ | If greater than 0.1 volt, test the BPPS low reference circuit for a short to voltage or an open/high resistance. If the circuit/connections test normal, replace the BCM. |
⇒ | If less then 4.7 volts, test the BPPS circuit for a short to ground or an open/high resistance. If the circuit/connections test normal, replace the BCM. |
⇒ | If greater than 5.2 volts, test the BPPS circuit for a short to voltage. If the circuit/connections test normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BCM replacement, setup and programming