Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
DEFINITION: The RH window does not operate from the LH window switch. | ||||||||
1 | Were you sent here from the DCM Diagnostic System Check? | -- | ||||||
2 | Check if any of the following DTCs are stored in the LDCM as history:
Are any of these DTCs stored as history? | -- | Go to the Applicable Table | |||||
3 | Using the RH window switch, operate the RH window UP and DOWN. Does the RH window operate? | -- | ||||||
4 | Using the LH window switch, operate the RH window UP and DOWN. Does the RH window operate? | -- | System OK | |||||
5 |
Does the scan tool display ACTIVE? | -- | ||||||
6 |
Does the scan tool display ACTIVE? | -- | System OK | |||||
7 | Check for an open in CKT 167 or CKT 150. Was a problem found and repaired? | -- | ||||||
8 | Check for an open in CKT 166 or CKT 150. Was a problem found and repaired? | -- | ||||||
9 | Replace the RH door switch assembly. Refer to Front Side Door Window Switch Replacement . Is the replacement complete? | -- | -- | |||||
10 |
Is the repair complete? | -- | System OK | -- |