The PCM continuously monitors the Heated Oxygen Sensor (HO2S) activity for 100 seconds. During the monitor period the PCM counts the number of times that the HO2S responds from rich to lean and from lean to rich and adds the amount of time it took to complete all transitions. With this information, the PCM can determine the average time for all transitions. If the average response time is too slow, a DTC will set.
The PCM determines the lean to rich transition when the HO2S voltage changes from less than 300 mV to greater than 600 mV. The PCM determines the rich to lean transition when the HO2S voltage changes from more than 600 mV to less than 300 mV. An HO2S that responds too slowly is most likely defective. Replace the HO2S.
• | DTCs P0101, P0102, P0103, P0112, P0113, P0117, P0118, P0125, P0200, P0335, P0336, P0351-P0358, P1120, P1220, P1221, P1258 are not set. |
• | The ignition voltage is greater than 9.0 volts. |
• | The fuel system is operating in Closed Loop. |
• | The engine speed is between 1000 RPM and 2300 RPM. |
• | The engine air flow between 20 g/s and 50 g/s. |
• | The EVAP canister purge duty cycle is greater than 0%. |
• | The engine run time is greater than 120 seconds. |
• | The lean to rich response (below 300 mV to above 600 mV) average time is greater than 250 milliseconds. |
• | The rich to lean response (above 600 mV to below 300 mV) average time is greater than 250 milliseconds. |
• | The above conditions are met for 60 seconds. |
• | The PCM illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The PCM records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the PCM stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the PCM records the operating conditions at the time of the failure. The PCM writes the conditions to the Freeze Frame and updates the Failure Records. |
• | The PCM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A last test failed, or current DTC, clears when the diagnostic runs and does not fail. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Use a scan tool in order to clear the MIL and the DTC. |
Important:
• Remove any debris from the PCM\TAC module connector surfaces before
servicing the PCM\TAC module. Inspect the PCM\TAC module connector gaskets
when diagnosing/replacing the modules. Ensure that the gaskets are installed
correctly. The gaskets prevent contaminate intrusion into the PCM\TAC
modules. • For any test that requires probing the PCM or a component
harness connector, use the Connector Test Adapter Kit J 35616
. Using this kit prevents damage
to the harness/component terminals. Refer to
Using Connector Test Adapters
in Wiring Systems.
• | A malfunction in the HO2S heater circuits will cause a DTC to set. Inspect the HO2S heater circuits for intermittent opens/connections. |
• | An oxygen supply inside the HO2S is necessary for proper operation. The HO2S wires provides the supply of oxygen. Inspect the HO2S wires and connections for breaks or contamination. Refer to Wiring Repairs in Wiring Systems. |
• | Using the Freeze Frame and/or Failure Records data may aid in locating an intermittent condition. If you cannot duplicate the DTC, the information included in the Freeze Frame and/or Failure Records data can help determine how many miles since the DTC set. The Fail Counter and Pass Counter can also help determine how many ignition cycles the diagnostic reported a pass and/or a fail. Operate the vehicle within the same freeze frame conditions (RPM, load, vehicle speed, temperature etc.) that you observed. This will isolate when the DTC failed. |
• | For an intermittent condition, refer to Symptoms . |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the fault is present. This test may take 5 minutes for the diagnostic to run.
When DTCs P0133 and P0153 are set at the same time, it is a good indication that a fuel contamination problem is present.
An exhaust leak 6-12 inches away from the HO2S can cause a DTC to set.
This step verifies whether a good ground circuit is available.
This step verifies the integrity of the signal circuit to the PCM.
This step verifies the integrity of the signal circuit to the PCM.
Certain RTV silicone gasket materials give off vapors that can contaminate the HO2S. There is also a possibility of silicone contamination caused by silicone in the fuel. If the sensors appear to be contaminated by silicone and all the silicone sealant is a non silicone base, advise the customer to try a different fuel company. A missing fuel filler restrictor indicates the customer may have used leaded fuel.
Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||||||||||
Important: If any DTCs are set (except P0133), refer to those DTCs before proceeding with this diagnostic table.
Did DTC P0153 fail this ignition? | -- | Go to Diagnostic Aids | ||||||||||
Did DTC P0133 also fail this ignition? | -- | |||||||||||
Did you isolate an exhaust leak? | -- | |||||||||||
Visually/physically inspect the following items:
Did you find and correct the condition? | -- | |||||||||||
Does the scan tool indicate a voltage within the specified range? | 350-550 mV | |||||||||||
Does the scan tool indicate a voltage below the specified value? | 200 mV | |||||||||||
Important: Determine and correct the cause of the contamination before replacing
a sensor. Inspect for the following conditions:
Replace the affected Heated Oxygen sensor. Refer to Heated Oxygen Sensor Replacement . Is the action complete? | -- | -- | ||||||||||
9 |
Does the DMM indicate a voltage near the specified value? | 5V | ||||||||||
10 | Repair the high signal circuit for a short to ground or a short to a voltage. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |||||||||
11 | Repair the open HO2S low circuit or repair the faulty PCM connections. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |||||||||
12 | Repair the HO2S high signal circuit for an open or repair the faulty PCM connections. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |||||||||
13 | Replace the HO2S. Refer to Heated Oxygen Sensor Replacement (Bank 2). Is the action complete? | -- | -- | |||||||||
14 |
Does the scan tool indicate that this test ran and passed? | -- | ||||||||||
15 | Select the Capture Info option and the Review Info option using the scan tool. Does the scan tool display any DTCs that you have not diagnosed? | -- | Go to the applicable DTC table | System OK |