Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The blower motor operates in high speed only. All other speeds are inoperative. | ||||
1 |
Is the voltage measured greater than the specified value? | 9 V | Go to Step 2 | Go to Step 3 |
2 |
Is the voltage measured less than the specified value? | 3 V | Go to Step 4 | Go to Step 3 |
3 | Repair the short to ground in CKT 754 (GRY/BLK). Was a short to ground repaired in CKT 754 (GRY/BLK)? | -- | Go to Step 6 | Go to Step 5 |
4 | Replace the blower control module. Refer to Blower Motor Control Module Replacement Is the repair complete? | -- | Go to Step 6 | -- |
5 | Replace the instrument panel integration module (IPM). Refer to Body Control Module Replacement Is the repair complete? | -- | Go to Step 6 | -- |
6 | Confirm proper operation of the blower motor. Is the blower motor operating correctly? | -- | System OK | -- |