Step

Action

Value(s)

Yes

No

Schematic Reference: HVAC Schematics

DEFINITION: The blower motor is inoperative in all speed positions.

1

Did you perform the HVAC Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - HVAC Systems - Automatic

2

  1. Turn ON the ignition, with the engine OFF.
  2. Place the blower motor switch in each speed position.

Does the blower motor operate in any speed position?

--

Go to Blower Motor Malfunction

Go to Step 3

3

  1. Place the blower motor switch in the maximum speed position.
  2. With a scan tool, observe the Commanded Blower parameter in the Instrument Panel Module data list.

Does the scan tool indicate that the Commanded Blower parameter is near the specified value?

96%

Go to Step 4

Go to Step 12

4

  1. Turn OFF the ignition.
  2. Disconnect the blower motor connector.
  3. Turn ON the ignition, with the engine OFF.
  4. Connect a test lamp between the blower motor supply voltage circuit and the blower motor control circuit.
  5. Place the blower motor switch in the minimum speed position.

Does the test lamp illuminate?

--

Go to Step 10

Go to Step 5

5

Test the battery positive voltage circuit of the blower motor control processor for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 6

6

Test the ground circuit of the blower motor control processor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 7

7

Important: Ensure that the blower motor control processor connector and the IPM connectors are connected during this step in order to avoid misdiagnosis.

  1. Measure the voltage from the blower motor speed control circuit of the IPM to a good ground.
  2. With a scan tool, command the blower motor OFF and ON.

Does the voltage measure near the specified values for each commanded state?

5.1 V OFF

0.67 V ON

Go to Step 11

Go to Step 8

8

  1. Turn OFF the ignition.
  2. Disconnect the IPM.
  3. Turn ON the ignition, with the engine OFF.
  4. Measure the voltage from the blower motor speed control circuit of the IPM to a good ground.

Does the voltage measure near the specified value?

5.0 V

Go to Step 12

Go to Step 9

9

Test the blower motor speed control circuit of the IPM for an open, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

 

Go to Step 16

Go to Step 11

10

Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 13

11

Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 14

12

Inspect for poor connections at the harness connector of the IPM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 16

Go to Step 15

13

Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

--

Go to Step 16

--

14

Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement .

Did you complete the replacement?

--

Go to Step 16

--

15

Important: Perform the recalibration procedure for the IPM.

Replace the IPM. Refer to HVAC Control Module Replacement .

Did you complete the replacement?

--

Go to Step 16

--

16

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 2