Blower Motor Control Processor Replacement LHD
Removal Procedure
- Remove the sound insulator.
Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gauges, and Console.
- Remove the instrument panel (IP) compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges, and Console.
- Remove the dash integration module (DIM). Refer to
Dash Integration Module Replacement
in Body Control
System.
- Remove the 2 rear DIM bracket fasteners.
- Reposition the DIM bracket in order to gain access to the blower
control module.
- Disconnect the blower
motor electrical connector (2).
- Disconnect the blower
control module electrical connector.
- Remove the blower control
module retaining fastener (1).
- Remove the blower control module.
Installation Procedure
- Install the blower control
module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower
control module retaining fastener (1).
Tighten
Tighten the fasteners to 1.4 N·m (12 lb ft).
- Connect the blower control
module electrical connector.
- Connect the blower motor
electrical connector (2).
- Reposition the DIM bracket
to its original position.
- Install the 2 rear DIM bracket fasteners.
Tighten
Tighten the fasteners to 1.4 N·m (12 lb ft).
- Install the DIM. Refer to
Dash Integration Module Replacement
in Body Control System.
- Install the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges, and
Console.
- Install the right sound insulator.
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gauges, and Console.
Blower Motor Control Processor Replacement RHD
Removal Procedure
- Remove the left sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gauges, and Console.
- Remove the IP compartment.
Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges, and Console.
- Remove the DIM from the bracket.
- Remove the 2 rear DIM bracket fasteners.
- Reposition the DIM bracket in order to gain access to the blower
control module.
- Disconnect the blower
control module electrical connector.
- Remove the blower control
module retaining fastener.
- Remove the blower control module.
Installation Procedure
- Install the blower control
module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower
control module retaining fastener.
Tighten
Tighten the fasteners to 1.4 N·m (12 lb ft).
- Connect the blower control
module electrical connector.
- Install the DIM bracket and fasteners.
- Install the DIM.
- Install the IP compartment.
Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges, and Console.
- Install the left sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gauges, and Console.