Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Measure the voltage between connector terminal B (BLK) and ground. Is the measure voltage within the specified range? | 10-15V | Go to Step 5 | Go to Step 3 | ||||
3 | Inspect CKT 99 (BLK/WHT) for an open or a short to ground. Is the wiring OK? | -- | Go to Step 6 | Go to Step 4 | ||||
4 | Repair the wiring on CKT 99 (BLK/WHT). Did you complete the repair? | -- | -- | |||||
5 | Measure the voltage between the connector terminal B (BLK) and connector terminal A (BLK). Is the measured voltage within the specified range? | 10-15V | Go to Step 11 | Go to Step 8 | ||||
6 | Inspect the following connectors for proper terminal contact:
Are the terminals OK? | -- | Go to Step 7 | Go to Step 13 | ||||
7 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the repair? | -- | -- | |||||
8 | Inspect CKT 1250 (BLK) for an open. Is the wiring OK? | -- | Go to Step 10 | Go to Step 9 | ||||
9 | Repair the open on CKT 1250 (BLK). Did you complete the repair? | -- | -- | |||||
10 | Inspect the in-line connector C201 for the proper terminal contact. Is the terminal OK? | -- | Go to Step 13 | |||||
11 | Inspect the washer fluid level switch connector for the proper terminal contact. Is the terminal OK? | -- | Go to Step 12 | Go to Step 13 | ||||
12 | Replace the washer fluid level switch. Did you complete the repair? | -- | -- | |||||
13 | Repair the poor terminal contact. Did you complete the repair? | -- | -- |