Diagnostic Instructions
Circuit/System Description
The HVAC control assembly applies a ground to the blower motor control circuit that corresponds to the selected blower speed. The resistors and the blower motor are in a series circuit. The following list represents the number of resistors in series with
the blower motor per particular speed request:
• | Medium 1 speed, 2 resistors |
• | Medium 2 speed, 1 resistors |
When the operator requests High speed, the HVAC control assembly applies ground to the high speed blower relay control circuit. When the relay contacts close, ground is applied directly to the blower motor through the blower motor resistor.
Reference Information
Schematic Reference
HVAC Schematics
Connector End View Reference
HVAC Connector End Views
Description and Operation
Electrical Information Reference
Scan Tool Reference
Circuit/System Verification
- Ignition ON, place the blower switch in the highest speed position, the blower motor should operate at High speed.
⇒ | If the blower motor does not function properly in the High speed position, perform the High Speed Blower Malfunction test. |
- Place the blower switch in Low, Medium 1 and Medium 2 speed positions. The blower motor should operate in each speed position.
⇒ | If the blower motor speed does not correspond with the selected switch position, perform the Blower Malfunction Test. |
Circuit/System Testing
High Speed Blower Malfunction
- Ignition OFF, disconnect the harness connector at the HVAC control module.
- Test for less than 1.0 ohm of resistance between the ground circuit terminal 4 and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Connect the harness connector at the HVAC control module.
- Disconnect the high speed blower relay.
- Place the blower switch in the high speed position.
- Test for less than 1.0 ohm of resistance between the ground circuit terminal 5 and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. If the circuit test normal test or replace the HVAC control module. |
- Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 2 and ground.
⇒ | If the test lamp does not illuminate, test the ignition circuit for an open/high resistance. |
- Test for less than 1.0 ohm of resistance between the ground circuit terminal 1 and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Connect the high speed blower relay. Disconnect the harness connector at the blower motor resistor.
- Ignition ON, place the blower switch in the high speed position.
- Test for less than 1.0 ohm of resistance between the control circuit terminal E at the blower motor resistor and ground.
⇒ | If greater than the specified range, test the control circuit for an open/high resistance. If the circuit test normal test or replace the high speed blower relay. |
- Ignition OFF, connect the harness connector at the blower motor resistor. Connect the high speed blower relay. Disconnect the harness connector at the blower motor.
- Ignition ON, place the blower switch in the high speed position.
- Verify that a test lamp illuminates between the control circuit terminal 1 and B+.
⇒ | If the test lamp does not illuminate, test the control circuit for an open/high resistance. |
⇒ | If the circuit test normal, test or replace the blower motor resistor. |
- Verify that a test lamp illuminates between the ignition circuit terminal 2 and ground.
⇒ | If the test lamp does not illuminate test the ignition circuit for an open/high resistance. |
- If all circuits test normal, test or replace the blower motor.
Blower Malfunction
- Ignition OFF, disconnect the harness connector at the HVAC control module.
- Test for less than 1.0 ohm of resistance between the ground circuit terminal 5 and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Connect the harness connector at the HVAC control module.
- Disconnect the harness connector at the blower motor resistor.
- Ignition ON, place the blower switch in the appropriate speed for the circuit being tested.
- Verify that a test lamp illuminates between the appropriate control circuit and B+.
⇒ | If the test lamp does not illuminate, test the appropriate control circuit for a short to ground or an open/high resistance. If the circuit test normal, test or replace the HVAC control module. |
- If all circuits test normal, test or replace the blower motor resistor.
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.