A/C Clutch-Actual: The scan tool displays On/Off. The HVAC control module displays On when the ECM transmits a class 2 message that the A/C compressor clutch relay is energized.
A/C Clutch--Desired: The scan tool displays Yes/No. The scan tool displays Yes when the HVAC control module determines that conditions for compressor clutch engagement are present.
A/C High Side Pressure : The scan tool displays 0-3450 kPa (0-500 psi). The voltage applied to the ECM input from the A/C refrigerant pressure sensor is converted to a pressure value.
A/C High Side Pressure : The scan tool displays 0-5 volts. The voltage applied to the ECM input for the A/C refrigerant pressure sensor.
A/C Pressure: The scan tool displays 0-3450 kPa (0-500 psi). The voltage applied to the ECM input from the A/C refrigerant pressure sensor is converted to a pressure value and transmitted in a class 2 message to the HVAC control
module.
A/C Relay Command: The scan tool displays On/Off. The scan tool displays the control decision for the compressor clutch relay output as determined by the ECM.
A/C Request Signal: The scan tool displays Yes/No. The scan tool displays Yes when the ECM receives a class 2 message from the HVAC control module to engage the A/C compressor clutch. The scan tool displays No when the ECM receives
a class 2 message from the HVAC control module to disengage the A/C compressor clutch.
Commanded Blower: The scan tool displays 0-100%. The scan tool displays the control decision for the blower motor speed as determined by the HVAC control module. The scan tool displays 100% when the blower motor is commanded to maximum
speed. The scan tool displays 0% when the blower motor is commanded OFF.
Coolant Temperature: The scan tool displays -39 to +140°C (-38 to +284°F) . The voltage applied to the ECM input from the engine coolant temperature sensor is converted to a temperature value and transmitted in a class
2 message to the HVAC control module.
Driver Temp Dr. Actual: The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the driver air temperature door position input of the HVAC control module.
Driver Temp Dr. Commanded: The scan tool displays 0-255 counts (0-5.00 Volts). The desired position of the driver air temperature actuator as determined by the HVAC control module.
Driver Solar Sensor: The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the driver sunload input of the HVAC control module.
Driver Sunload: The scan tool displays 0-2000 w/m2. The voltage applied to the driver sunload input of the HVAC control module converted to light intensity units.
ECT Sensor: The scan tool displays -39 to +140°C (-38 to +284°F) . The voltage applied to the ECM input from the engine coolant temperature sensor is converted to a temperature value.
ECT Sensor: The scan tool displays 0-5 volts. The voltage applied to the ECM input for the engine coolant temperature sensor.
Evaporator Temp: The scan tool displays -39 to +140°C (-38 to +284°F). The voltage applied to the HVAC control module input from the evaporator temperature sensor is converted to a temperature value.
Evaporator Temp: The scan tool displays 0-255 counts (0-5 Volts). The voltage applied to the HVAC control module input for the evaporator temperature sensor.
Htr./Def./A/C Dr. Actual: The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the mode door position input of the HVAC control module.
Htr./Def./A/C Dr. Commanded: The scan tool displays 0-255 counts (0-5.00 Volts). The desired position of the mode actuator as determined by the HVAC control module.
Inside Air Temp.: The scan tool displays -40 to +215°C (-40 to +419°F). The voltage applied to the HVAC control module input for the inside air temperature sensor is converted to a temperature value.
Inside Air Temp.: The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the HVAC control module input for the inside air temperature sensor.
Low Coolant Status: The scan tool displays OK/Low. The filtered state of the low coolant switch.
Low Coolant Switch: The scan tool displays Open/Closed. The actual state of the low coolant switch.
Outside Air Temp. : The scan tool displays -40 to +215°C (-40 to +419°F). The current value of the ambient air temperature display on the HVAC control module.
Outside Air Temp. : The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the HVAC control module input for the outside air temperature sensor.
Passenger Solar Sensor: The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the passenger sunload input of the HVAC control module.
Passenger Sunload: The scan tool displays 0-2000 w/m2. The voltage applied to the driver sunload input of the HVAC control module converted to light intensity units.
Passenger Temp Dr. Actual: The scan tool displays 0-255 counts (0-5.00 Volts). The voltage applied to the passenger air temperature door position input of the HVAC control module.
Passenger Temp Dr. Commanded: The scan tool displays 0-255 counts (0-5.00 Volts). The desired position of the passenger air temperature actuator as determined by the HVAC control module.
Pressure Sensor: The scan tool displays OK/Failed. The state of the A/C refrigerant pressure sensor and circuitry.