Battery voltage is supplied to the CVRSS control module at connector C1, terminal B1. The CVRSS control module monitors the supplied battery voltage to determine if it is within a valid operating range.
• | DTC C1326 sets when the battery voltage is above 15.5 volts. |
• | DTC C1326 sets when the battery voltage falls below 9.0 volts. |
• | DTC C1326 clears when the battery voltage is less than 15.0 volts. |
• | DTC 1326 clears when the battery voltage is greater than 9.5 volts. |
• | DTC C1326 disables the ability to set most other CVRSS DTCs. |
• | DTC C1326 may set when the vehicle is placed on a battery charger, on fast charge, for a long period of time. |
The number(s) below refer to the step number(s) on the diagnostic table.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Is the measurement within the specified values? | 9-15.5 V | Go to Step 2 | Go to Charging System Check in Engine Electrical | |
2 |
Important: The controller must be calibrated. Is the CVRSS control module calibrated? | -- | Go to Step 3 | -- |
3 | Clear the DTCs from memory. Refer to Clearing DTCs . Are the DTCs cleared from memory? | -- | -- |