• | The engine coolant temperature sender (2) |
• | The engine coolant temperature sensor (4) |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the engine oil cooler cover bolts to 30 N·m (22 lb ft).
Tighten
Tighten the engine oil cooler inlet and outlet nuts to 20 N·m
(15 lb ft).
Use 4 new seals.
Tighten
Tighten the oil feed and return lines to 30 N·m (22 lb ft).
• | Position the crossover. |
• | Install the upper and lower seals (2). |
• | Install the water crossover bolts (1). |
Tighten
Tighten the water crossover bolts to 30 N·m (22 lb ft).
• | The engine coolant temperature sensor (4) |
• | The engine coolant temperature sender (2) |
Tighten
Tighten the oil cooler outlet (1) line to 30 N·m
(22 lb ft).
Tighten
Tighten the oil cooler inlet (2) line to 30 N·m
(22 lb ft).
Tighten
Tighten the oil filter housing to 45 N·m (33 lb ft).