Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Did you find a short to voltage on CKT FP812? | -- | ||
2 | Repair the short to voltage on CKT FP812 (BLK/BLU). Did you complete the repair? | -- | -- | |
3 | Disconnect the blower motor ground (BRN wire) from the blower control module. Did the blower motor stop operating? | -- | ||
4 |
Do all the blower speeds operate properly? | -- | System OK | |
5 | Replace the blower control module. Did you complete the replacement? | -- | -- | |
6 | Replace the heater & A/C control. Refer to Control Assembly Replacement . Did you complete the replacement? | -- | -- | |
7 | Replace the blower motor. Refer to Blower Motor and Fan Replacement in HVAC. Did you complete the replacement? | -- | -- | |
8 | Operate the system for which the symptom occurred. Is the symptom still present? | -- | -- | System OK |