Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the voltage equal the specified value? | 6 V | Go to Step 2 | Go to Step 4 |
2 | Reconnect the blower motor connector. Does the blower motor run on high speed? | -- | Go to Step 3 | System OK |
3 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | System OK | -- |
4 | Measure the voltage at terminal C of the blower control module input. Refer to Measuring Voltage in Wiring Systems. Does the voltage equal the specified value? | 4-5 V | Go to Step 5 | Go to Step 6 |
5 | Replace the blower control module. Refer to Blower Motor Control Module Replacement . Is the repair complete? | -- | System OK | -- |
6 | Replace the HVAC programmer. Refer to Programmer Replacement . Is the repair complete? | -- | System OK | -- |