Removal Procedure
- Remove the right side
sound insulator. Refer to
Instrument Panel Insulator Panel Replacement
in Instrument Panel, Gauges, and Console.
- Disconnect the electrical connector from the blower motor.
- Remove the cooling tube from the blower motor.
- Remove the fasteners that attach the blower motor to the heater
and A/C module assembly.
- Remove the blower motor and fan assembly.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower
motor to the heater and A/C module assembly using the attaching fasteners.
Tighten
Tighten the fasteners to 1 N·m (12 lb in).
- Install the cooling tube to the blower motor.
- Connect the electrical connector to the blower motor.
- Install the right side sound insulator. Refer to
Instrument Panel Insulator Panel Replacement
in
Instrument Panel, Gauges, and Console.