Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the voltage greater than the specified value? | 8 Volts | ||
2 | Using a DMM, measure the voltage from the BATT terminal (RED) and ground. Is the voltage greater than the specified value? | 8 Volts | ||
3 |
Is the voltage between the specified values? | 13.3 -15.5 Volts | ||
4 |
Did you find and correct the condition? | -- | Go to Charging System Check | -- |
5 | Check for open or poor connections in CKT 225, (RED), between the generator terminal L and the PCM connector C2, terminal 35. Did you find and correct the condition? | -- | Go to Charging System Check | -- |
6 | Check for an open in CKT 1 between the generator BATT terminal and the battery. Did you find and correct the condition? | -- | Go to Charging System Check | -- |
7 | Replace the generator. Did you correct the condition? | -- | Go to Charging System Check | -- |