Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the charging system check performed? | -- | Go to Charging System Check | Go to Step 2 |
2 | Check the connections at the battery and the generator. Was a poor connection found? | -- | ||
3 | Is the battery fully charged? | 12 V | ||
4 |
Is the voltage output at the specified value? | 14 V* | ||
5 |
Is the output is within 15 amps of the rated output? | 124 A | System OK | |
6 | Repair the connector as required. Is the repair complete? | -- | -- | |
7 | Charge the battery. Refer to Battery Charging . Is the battery fully charged? | -- | ||
8 | Replace the generator. Refer to Generator Replacement . Is the replacement complete? | -- | System OK | -- |
* Cold engine temperature voltage 14.0 - 16.0. The voltage should be between 13.0 and 15.0 when the engine is at the operating temperature. |