Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |
2 |
Does the resistance measure within the specified range? | 0-5 ohms | Go to Step 4 | Go to Step 3 |
3 | Repair the open or high resistance in CKT 780 (RED/BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 | Inspect for poor terminal contact at the inoperative front power door lock switch connector. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the terminal contact OK? | -- | Go to Step 6 | Go to Step 5 |
5 | Repair the terminal contact at the front power door lock switch connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Replace the inoperative front power door lock switch. Refer to one of the following procedures: Is the repair complete? | -- | -- |