Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |
2 |
Does the voltage measure within the specified range with the switch pressed? | 10-15 V | Go to Step 4 | Go to Step 3 |
3 | Repair the open in CKT 294 (TAN) between the door lock actuator connector terminal A and S302. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 |
Does the voltage measure within the specified range with the switch pressed? | 10-15 V | Go to Step 6 | Go to Step 5 |
5 | Repair the open in CKT 295 (GRY) between the door lock actuator connector terminal B S303. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Inspect for poor terminal contact at the door lock actuator connector. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the terminal contact OK? | -- | Go to Step 8 | Go to Step 7 |
7 | Repair the terminal contact at the door lock actuator connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Replace the inoperative door lock actuator. Refer to Door Lock Replacement . Is the repair complete? | -- | -- |