Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |
2 |
Does the resistance measure within the specified range? | 0-5 ohms | Go to Step 6 | Go to Step 3 |
3 | Test for an open in CKT 1250 (BLK) from SP 304 to the inoperative front power door lock switch. Is CKT 1250 open? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair the open in CKT 1250 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 | Inspect for poor terminal contact at the inoperative front power door lock switch. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the connector terminal contact OK? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the terminal contact at the front power door lock switch connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
7 | Replace the inoperative front power door lock switch. Refer to one of the following procedures: Is the repair complete? | -- | -- |