GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Saturn
🢒
2009
🢒
VUE - AWD
🢒
Transmission
🢒
Automatic Transmission - 2MT70
🢒 Range Selector Lever Cable Bracket Replacement
Removal Procedure
Remove the power inverter module. Refer to
Drive Motor Generator Power Inverter Module Removal and Installation
Disconnect the range select cable (2) from the range select lever.
Release the range select cable retaining clip (1) and remove the cable from the range select cable bracket.
Remove the bolts (1) securing the range select lever cable bracket.
Remove the range select lever cable bracket (2).
Installation Procedure
Install the range select lever cable bracket (2).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the bolts (1) securing the range select lever cable bracket, then tighten the bolts to
25 N·m (18 lb ft)
.
Install the range select cable to the range select cable bracket. Ensure the range select cable retaining clip (1) is secured in the bracket.
Connect the range select cable (2) to the range select lever.
Adjust the cable. Refer to
Range Selector Lever Cable Adjustment
.
Install the power inverter module. Refer to
Drive Motor Generator Power Inverter Module Removal and Installation