🢒 Camshaft Position Sensor Replacement - Bank 1 (Right Side) Intake
Removal Procedure
Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.
Disconnect the engine wiring harness electrical connector (3) from the bank 1 intake camshaft position (CMP) sensor (4).
Remove the CMP sensor bolt.
Remove the CMP sensor.
Installation Procedure
Install the CMP sensor.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the CMP sensor bolt. Tighten the bolt to
10 N·m (89 lb in).
Connect the engine wiring harness electrical connector (2) to the bank 1 intake CMP sensor (4).
Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.