Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Wiper/Washer Schematics Connector End View Reference: Wiper/Washer Connector End Views DEFINITION: The low washer fluid indicator always indicates low washer fluid or does not illuminate when washer fluid is low. | |||
1 | Verify the fault is present. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 2 |
2 |
Does the low washer fluid indicator illuminate? | Go to Step 5 | Go to Step 3 |
3 |
Does the low washer fluid indicator illuminate? | Go to Step 4 | Go to Step 6 |
4 |
Does the low washer fluid indicator illuminate? | Go to Step 8 | Go to Step 7 |
5 | Test the low washer fluid indicator signal circuit for a short to ground. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 10 |
6 | Test the low washer fluid indicator signal circuit for an open or high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 10 |
7 | Repair the washer fluid level switch ground circuit for an open or high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the replacement? | Go to Step 12 | -- |
8 | Inspect for poor connections at the washer fluid level switch. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 9 |
9 | Replace the washer fluid level switch. Refer to Washer Pump/Reservoir Replacement . Did you complete the replacement? | Go to Step 12 | -- |
10 | Inspect for poor connections at the instrument panel cluster. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 11 |
11 | Replace the instrument panel cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement? | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |