Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the blower motor electrical connector.
- Remove the blower cooling hose.
- Remove the screws that secure the motor to the heater/air distribution case.
- Remove the motor and the seal from the heater/air distribution case by gently pulling the motor straight down and out.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the blower motor and seal, with the shock mount pads, in the heater/air distribution case. Hold the blower motor in position.
- Install the screws to secure the blower motor to the heater/air distribution case.
Tighten
Tighten the blower motor retaining screws to 6 N·m (53 lb in).
- Install the blower motor cooling hose.
- Connect the electrical connector.
- Connect the negative battery cable.
- Confirm that the blower motor operates properly.