Removal Procedure
- Discharge and recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Disconnect the A/C refrigerant pressure switch electrical connector (1).
- Remove the A/C refrigerant pressure switch (2). Use a second wrench to hold the switch mount to avoid bending the liquid line.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
Note:
• | Use new O-rings lubricated with 525 viscosity mineral oil. |
• | Hold the A/C refrigerant pressure switch mount with an open end wrench to avoid bending the liquid line. |
- Install the A/C refrigerant pressure switch (2).
Tighten
Tighten the A/C refrigerant pressure switch (2) to 11 N·m (8.0 lb ft).
- Connect the A/C refrigerant pressure switch electrical connector (1).
- Evacuate and recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging.
- Operate the A/C system and check for leaks. Refer to
Leak Testing.