Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Component Connector End Views | |||
1 | Did you review the Power Door system Description and Operation? | Go to Step 2 | |
2 | Disable the dome lamp override switch. Is the dome lamp or the door ajar indicator always on? | Go to Dome Lamps Always On | Go to Step 3 |
3 | Open each door individually while observing the dome lamps. Does the dome lamp illuminate with each door? | Go to Step 4 | Go to Dome Lamps Inoperative |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 | Inspect for poor connections at the IPC connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
6 | Test for a short to ground in the door ajar indicator control circuit between the multifunction alarm module and the IPC. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 7 |
7 | Inspect for poor connections at the multifunction alarm module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 8 |
8 | Replace the body control module (BCM). Refer to Control Module References . Did you complete the replacement? | Go to Step 10 | |
9 | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | Go to Step 10 | |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |