Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics | ||||||||||
1 | Did you review the Diagnostic Starting Point for Engine Electrical and perform the necessary inspections? | -- | Go to Step 2 | |||||||
2 |
Note: The battery must be above a 70 percent state of charge. Did you perform the Battery Inspection Test? | -- | Go to Step 3 | Go to Battery Inspection/Test | ||||||
3 |
Is the voltage measured within the specified value? | 12.0-15.5 V | Go to Step 4 | Go to Step 5 | ||||||
4 |
Warning: Make sure that the load is completely turned off before connecting or disconnecting a carbon pile load tester to the battery. Otherwise, sparking could ignite battery gasses which are extremely flammable and may explode violently. Note: When measuring generator output current, be sure the inductive probe encircles the generator output wire. Is the generator output greater than or equal to the load test value as specified in Generator Usage ? | -- | Go to Step 15 | Go to Step 6 | ||||||
5 | Is the voltage measured greater than the specified value? | 15.5 V | Go to Step 9 | Go to Step 6 | ||||||
6 |
Does the voltage measure near the specified value? | B+ | Go to Step 7 | Go to Step 11 | ||||||
7 |
Is the voltage above the specified value? | 0.5 V | Go to Step 12 | Go to Step 8 | ||||||
8 |
Is the voltage above the specified value? | 0.5 V | Go to Step 13 | Go to Step 10 | ||||||
9 | Test the sense circuit of the generator for a high resistance. Refer to Circuit Testing and Wiring Repairs. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 10 | ||||||
10 | Inspect for poor connection at the generator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 14 | ||||||
11 | Repair the high resistance or open in the generator turn ON signal circuit. Refer to Wiring Repairs. Did you complete the repair? | -- | Go to Step 15 | -- | ||||||
12 | Repair the high resistance in the battery positive circuit between the generator output terminal and the battery positive terminal. Refer to Wiring Repairs. Did you complete the repair? | -- | Go to Step 15 | -- | ||||||
13 | Repair the high resistance in the ground circuit between the generator housing and the battery negative terminal. Refer to Wiring Repairs. Did you complete the repair? | -- | Go to Step 15 | -- | ||||||
14 | Replace the generator. Refer to Generator Replacement. Did you complete the repair? | -- | Go to Step 15 | -- | ||||||
15 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 1 |