Removal Procedure
First Design
- Disconnect the electrical connector (1)
from the secondary AIR pressure sensor (2).
- Remove the fastener (4) from the secondary AIR shut off valve (3).
- Remove the secondary AIR pressure sensor (2) from the shut off
valve (3).
Installation Procedure
- Install the secondary AIR pressure sensor (2)
to the shut off valve (3) with the one fastener (4).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Tighten the secondary AIR pressure sensor fastener (4).
Tighten
Tighten the fastener to 8.8 N·m (77 lb in).
- Connect the electrical connector (1) to the AIR pressure sensor (2).
Removal Procedure
Second Design
- Disconnect the electrical connector (1) from the
secondary AIR pressure sensor (2).
- Remove the two fasteners of the AIR pressure sensor (2).
- Remove the secondary AIR pressure sensor (2) from the shut off
valve (3).
Installation Procedure
- Install the secondary AIR pressure sensor (2)
to the shut off valve (3).
- Secure the secondary AIR pressure sensor with two fasteners.
Tighten
Tighten the fasteners to 5.0 N·m (44 lb in).
- Connect the electrical connector (1) to the AIR pressure sensor (2).