Removal Procedure
- Remove the case side cover pan. Refer to
Control Valve Body Cover Replacement
.
- Remove the electrical connections from
the shift solenoids.
Important: Do not remove the bolts which hold the pump together.
- Remove the pump to valve body bolts.
- Inspect the pump. Refer to
Oil Pump Disassemble
.
Installation Procedure
- Install the pump to the valve body.
- Install the valve body bolts.
Tighten
• | Tighten the M6 bolts to 11 N·m (97 lb in). |
• | Tighten the M8 bolts to 24 N·m (18 lb ft). |
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the electrical connections to
the shift solenoids.
- Install the case side cover pan. Refer to
Control Valve Body Cover Replacement
.
- Adjust the fluid level.
- Inspect for the following:
• | Proper completion of repairs |