GM Service Manual Online
For 1990-2009 cars only

Test Description

The number below refers to the step number on the diagnostic table.

  1. This step tests the heater blower relay control circuit.

Step

Action

Yes

No

Schematic Reference: HVAC Schematics

Connector End View Reference: HVAC Connector End Views

DEFINITION: The blower motor is inoperative in all speed positions.

1

Did you perform the Diagnostic System Check - Vehicle?

Go to Step 2

Go to Diagnostic System Check - Vehicle in Vehicle DTC Information

2

Important: The mode switch must remain in any position except OFF throughout this diagnostic procedure.

  1. Turn ON the ignition, with the engine OFF.
  2. Place the mode switch in any position except OFF.
  3. Place the blower motor switch in each speed position.

Does the blower motor operate in any speed position?

Go to Blower Motor Malfunction

Go to Step 3

3

  1. Turn OFF the ignition.
  2. Disconnect the blower motor.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the blower motor supply voltage circuit of the blower motor with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 4

Go to Step 7

4

Connect a test lamp between the blower motor supply voltage circuit and the high blower motor control circuit of the blower motor.

Does the test lamp illuminate?

Go to Step 13

Go to Step 5

5

Test the high blower motor control circuit for an open, short to voltage or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 6

6

Test the blower motor switch ground circuit of the HVAC control assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 14

7

Test the blower motor supply voltage circuit of the blower motor for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 8

8

  1. Turn OFF the ignition.
  2. Disconnect the heater blower relay.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the battery positive voltage circuit of the blower motor relay with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 9

Go to Step 15

9

  1. Turn OFF the ignition.
  2. Disconnect the heater blower relay.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the heater blower relay ignition 3 voltage supply circuit with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 10

Go to Step 11

10

Test the ground circuit of the heater blower relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 12

11

Test the heater blower relay ignition 3 voltage supply circuit for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 12

12

Inspect for poor connections at the heater blower relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 17

13

Inspect for poor connections at the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 18

14

Inspect for poor connections at the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 20

Go to Step 19

15

Repair the battery positive voltage circuit of the heater blower relay. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

Go to Step 20

--

16

Repair the ignition 3 voltage circuit of the HVAC control assembly. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

Go to Step 20

--

17

Replace the heater blower relay. Refer to Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

Go to Step 20

--

18

Replace the blower motor. Refer to Blower Motor Replacement in Heating Ventilation and Air Conditioning.

Did you complete the replacement?

Go to Step 20

--

19

Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement .

Did you complete the replacement?

Go to Step 20

--

20

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 2