This tests for blower motor functionality.
This tests if A/C compressor function is inoperative.
This tests for A/C compressor engagement. Ambient air temperature must be above 3°C (38°F) for the compressor to engage.
Step | Action | Values | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Definition: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | ||||||||||||
1 | Did you perform the HVAC Diagnostics System Check? | -- | Go to Step 2 | |||||||||
Does the blower motor operate in any of the speed positions? | -- | Go to Step 3 | Go to Blower Motor Inoperative | |||||||||
3 | Does the blower motor operate at the desired speeds? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||
4 |
Does the recirculation door move to the recirculation position? | -- | Go to Step 5 | |||||||||
When the A/C is ON, does the customer concern occur? | -- | Go to Step 6 | Go to Step 8 | |||||||||
Important: The ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 7 | ||||||||||
7 | Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 8 | ||||||||
8 | Inspect the air temperature door and linkage for the following conditions:
Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 9 | ||||||||
9 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 | ||||||||
10 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- | ||||||||
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |